Precautions for installing and using the ozone generator

Ozone generators are innovative devices that have gained popularity in recent years because they can effectively remove odors, kill bacteria, and remove pollutants from the environment using the power of ozone. The correct use of the ozone generator can effectively avoid the occurrence of danger, let the ozone generator play a greater role, and create a healthier and safer environment.

Precautions when installing an ozone generator

1. Please turn off the power for a long shutdown.

2. Use with caution in flammable and explosive areas.

3.Maintenance and maintenance of the ozone generator should be carried out without electricity and pressure.

4. The continuous use time of the ozone generator is generally maintained for more than 4 hours each time.

5. Regularly check electrical parts for moisture, good insulation (especially high voltage areas) and good grounding.

6. The ozone generator should always be installed in a dry, well-ventilated and clean environment, and the shell should be securely grounded. Ambient temperature: 4°C to 35°C, relative humidity: 50% to 85% (non-condensing).

7. If the ozone generator is found or suspected to be wet, the machine should be tested for insulation and dry measures should be taken. The power button should only be activated when isolation is in good condition.

8. Regularly check to see if the vents are unobstructed and covered. Never block or cover the ventilation openings.

9. After using the ozone generator for a period of time, open the shield and carefully remove the dust inside the shield with alcohol swabs.

Precautions when using an ozone generator

1. Oxygen-type ozone generators should take special care not to use open flames nearby to prevent oxygen explosion.

2. The ozone release tube of the ozone generator should be replaced once a year under normal circumstances.

3. The ozone generator cannot be turned upside down during transportation. All equipment should be checked before operation.

4. Place the ozone generator in a well-ventilated and dry place, if the surroundings of the machine get wet, it will leak electricity and the machine cannot work normally.

5. The voltage regulator should gradually increase the pressure during the pressure regulation process.

6. The desiccant in the ozone drying system should be replaced every six months, if the cooling water enters the ozone generator, immediately stop it, completely disassemble the exhaust system, replace the exhaust tube and desiccant need to do it.

OZONE GENERATOR